Applicable also for Olivetti, Develop and Aurora devices.
Compatible blocking cables
-
YSQC0-004-0000 Cable KM KeyCounter – Male
-
YSQC0-005-0000 Cable KM KeyCounter – Female
-
YSQC0-039-0000 KM Vender2 v5 (8-pin)
-
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Configuration of device using Key counter cable(YSQC0-004-0000, YSQC0-005-0000)
-
Enter service menu of the device
-
Press STOP - 9
-
Click on Counter settingsTotal counter mode must be setup on MODE 2 and large size counter mode must be setup on "A3/B4/11x17/8½x14".
-
Click on Management function choiceIn Authentication device must be setup Key counter onlyIn this menu is also possible to change type of predefined message which is displayed in case of blocked panel.Item Key counter > Message1-Message4
Configuration of device using Key counter cable on bizhub PRESS
-
Switch-off the MFD
-
Uncover the MFD in order to allow access to a Key counter connector
-
Unplug a small yellow/beige plug which covers the Key counter connector
-
Connect the Key counter blocking cable to the Key counter connector
-
Switch-on the MFD
-
Verify that the MFD is blocked (message Please insert key counter is displayed on the MFD panel) and can be unblocked by the terminal
Configuration of device using KM Vender2 cable(YSQC0-039-0000, YSQC0-044-0000)
Leaving the blocking cable connected to MFD and disconnecting it from Terminal Professional/Ultralight may cause inability to start the MFD or infinite reboots of the MFD.
-
Enter service menu of the device
-
Press STOP - 9
-
Click on Counter settings
Total counter mode must be setup on MODE 2 and large size counter mode must be setup on "A3/B4/11x17/8½x14". -
Click on Management function choiceIn Service menu > Management function choice > must be setup vender 2
Alternative configuration for bizhub C3350 (firmware A3GN30G0206-999 or newer required)
-
Enter service menu of the device
-
Press STOP > 2 > 2 > 2 > 0 > 0
-
Click on Counter settings
Total counter mode must be setup on MODE 2 and large size counter mode must be setup on "A3/B4/11x17/8½x14". -
Click on Management function choiceIn Service menu > Management function choice > must be setup vender 2
Additional setting
To enable printing with Vender 2 cable setup:
Tools/counters > 3 Administrator setting > 9 Security Setting > 7 Management Function setting > 1 Function setting
-
Copy – ON
-
Print – OFF
-
Send Scan/Fax – ON
Examples of blocking cable connection:
KM bizhub C364
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment Unknown Attachment Unknown Attachment
KM bizhub C364
YSQC0-004-0000 Cable KM KeyCounter – Male
Unknown Attachment Unknown Attachment Unknown Attachment
KM bizhub C554
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment
KM bizhub C654 / C754 / C654e / C754e
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment Unknown Attachment
KM bizhub PRESS 1250
YSQC0-004-0000 Cable KM KeyCounter – Male
If the depicted wire conjunction is present (default state) - the device is unblocked.
If this is removed - device becomes blocked and blocking cable can be attached and used for un-blocking.
Unknown Attachment Unknown Attachment Unknown Attachment
KM bizhub PRESS C6000
YSQC0-004-0000 Cable KM KeyCounter – Male
If the depicted wire conjunction is present (default state) - the device is unblocked.
If this is removed - device becomes blocked and blocking cable can be attached and used for un-blocking.
Unknown Attachment Unknown Attachment Unknown Attachment
KM bizhub C224e / C284e / C364e / C454e / C554e / 224e / 284e / 364e / 454e / 554e
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment Unknown Attachment
KM bizhub Cxx4e / xx 4e
YSQC0-004-0000 Cable KM KeyCounter – Male
Unknown Attachment
KM bizhub C368/C308/C258
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin, Type2)
Unknown Attachment
YSQC0-004-0000 Cable KM KeyCounter Male
Unknown Attachment
KM bizhub 758/808/958
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin, Type2)
Unknown Attachment
YSQC0-004-0000 Cable KM KeyCounter Male
Unknown Attachment
KM bizhub C3350/C3850
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment
KM bizhub C3351/C3851
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment
KM bizhub C659/C759
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin,Type2)
Unknown Attachment
YSQC0-004-0000 Cable KM KeyCounter Male
Unknown Attachment
KM bizhub 4052/4752
YSQC0-044-0000 Smart Cable KM Vender2 v5 (8-pin, Type2)
Unknown AttachmentUnknown Attachment
Smart Blocking Cables for Hardware Terminals
Required for copy control
YSQC0-044-0000
Smart Cable KM Vender2 v5 (8-pin,Type2)
YSQC0-039-0000
Smart Cable KM Vender2 v5 (8-pin)
YSQC0-038-0000
Smart Cable KM Vender2 v5 (9-pin)
YSQC0-005-0000
Smart Cable KM Key-counter - Female SSR - (TP)
YSQC0-004-0000
Smart Cable KM Key-counter - Male SSR - (TP)